Configuration.

Configuring and using

1. Create an output transport of the type "Serial" directly or by the "Sockets" gate, and set its Identifier like to "IEC62056", one for each the devices' used serial bus.
2. Set proper address and timeouts of the Serial device.
3. Create and start a logical controller object or use any present one with need scheduling properties. The interaction period preferred to be about 0.1 second.
4. Create a logical parameter object and select the template for that, one for each the device-PLC — enable the parameter.
5. Into the tab "Template configuration" of the logical parameter object you need to set:
  • Transport — to address of the transport into step 1. Tracing for the address changing is supported.
  • Destination "{UHDLC}[:{LHDLC}]" — remote station address in the two digits format each of which in the range [0...16383], this address can be pointed as one digit of the range [0...127].
  • Source — the same station address (source) in the integer range [0...127].
  • Password the device — the device access password.
  • Retry connection time — retry connection time in seconds, at the connection missing and no response detection.
  • Poll all time — time in seconds of the complete data requesting, pointed in the "itemsSet".
6. RESULT: The logical parameter object will perform interaction and placing of the gathered data to the object "items", creation/placing the gathered data to the proper value attributes.
7. In the process of the working, through the tab "Attributes" of operational data, in addition to obtaining the result, it is possible to perform operative setup and control on:
  • Items set by — for appending the device's OBIS to their reading.