From OpenSCADAWiki
Enter a message name below to show all available translations.
Found one translation.
Name | Current message text |
---|---|
h English (en) | {{CntHdr|Template IOs}} {| class="mw-collapsible mw-collapsed wikitable sortable" |+ style=white-space:nowrap | |- ! Identifier !! Parameter !! Type !! Mode !! Attribute !! Configuration !! Value |- | transport || Transport || String || Input || Not attribute || Constant || Serial.goboy |- | addr || Device address [0...247] || Integer || Input || Not attribute || Constant || 1 |- | arhH || OpenSCADA archiver for device's archive of hours || String || Input || Not attribute || Constant || |- | arhD || OpenSCADA archiver for device's archive of days || String || Input || Not attribute || Constant || |- | arhM || OpenSCADA archiver for device's archive of months || String || Input || Not attribute || Constant || |- | arhTryPer || Currents try period, seconds || Integer || Input || Not attribute || Constant || 3600 |- | arhTmLim || Time limit of processing the archiving, seconds || Integer || Input || Not attribute || Constant || 40 |- | reset || Reset the archives reading and configuration || Boolean || Input || Full access || Variable || |- | devManuf || Device manufacturer || String || Input || Read only || Variable || |- | devNameVer || Device name and SW version || String || Input || Read only || Variable || |- | devSN || Device SN || String || Input || Read only || Variable || |- | batV || Battery voltage || Real || Input || Read only || Variable || |- | batMinV || Battery minimum voltage || Real || Input || Read only || Variable || |- | baseL || Base length, mm || Real || Input || Read only || Variable || |- | baseD || Base diameter, mm || Real || Input || Read only || Variable || |- | sndSpd || Sound speed, m/s || Real || Input || Read only || Variable || |- | flowSpd || Flow speed, m/s || Real || Input || Read only || Variable || |- | p || Gas P, kPa [arh] || Real || Input || Read only || Variable || |- | t || Gas T, °С [arh] || Real || Input || Read only || Variable || |- | coefCompr || Coefficient of the compression || Real || Input || Read only || Variable || |- | notWorkTm || Not work time [arh] || Integer || Input || Read only || Variable || |- | curTm || Current time || String || Input || Full access || Variable || |- | arhStart || Archive begin || String || Input || Read only || Variable || |- | arhLastH || Archive last hour || String || Input || Read only || Variable || |- | arhLastD || Archive last day || String || Input || Read only || Variable || |- | arhLastM || Archive last month || String || Input || Read only || Variable || |- | cntH || Count hour || Integer || Input || Full access || Variable || |- | vWork || Volume: work, m3 [arh] || Real || Input || Read only || Variable || |- | vAccWork || Volume: accumulated work, m3 [arh] || Real || Input || Read only || Variable || |- | vResult || Volume: resume, m3 [arh] || Real || Input || Read only || Variable || |- | vAccResult || Volume: accumulated resume, m3 [arh] || Real || Input || Read only || Variable || |- | fWork || Flow: work, m3/h || Real || Input || Read only || Variable || |- | fResult || Flow: resume, m3/h || Real || Input || Read only || Variable || |- | arhs || Archives object || Object || Output || Not attribute || Variable || |- | tr || Output transport || Object || Output || Not attribute || Variable || |- | this || Object of the parameter || Object || Input || Not attribute || Variable || |- | f_stop || Function stop flag || Boolean || Input || Not attribute || Variable || 0 |- | f_err || Function error || String || Input || Not attribute || Variable || 0 |- | f_start || Function start flag || Boolean || Input || Not attribute || Variable || 0 |- | f_frq || Frequency of calculation of the function, Hz || Real || Input || Not attribute || Variable || 1000 |} |