Name | Current message text |
---|---|
h English (en) | {{CntHdr|Configuring and using}} :1. Create an output transport of the type "[[Special:MyLanguage/Modules/Sockets|Sockets]]" or "[[Special:MyLanguage/Modules/Serial|Serial]]" and set its Identifier like to "BK", one for each the device. :2. Set proper address and timeouts of the [[Special:MyLanguage/Modules/Sockets|Sockets]] or [[Special:MyLanguage/Modules/Serial|Serial]] device. :3. Create and start [[Special:MyLanguage/Modules/LogicLev|a logical controller object]] or use any present one with need scheduling properties — must be set in the period 10...60 seconds. :4. Create [[Special:MyLanguage/Modules/LogicLev|a logical parameter object]] and select the template for that, one for each the devices — enable the parameter. :5. Into the tab "Template configuration" of the logical parameter object you need to set: :* ''Transport'' — to Identifier of the transport in step 1. :* ''Device address [0...15]'' — to logical address of the device on the bus under the transport in step 1. Tracing for the address changing is supported. :* ''Current values request in regular'' — a sign of requesting current values in regular, which can be disabled for saving the device battery. :* ''OpenSCADA archiver for device's archive of hours'' — set to the value archiver whole ID like to "FSArch.1h" for an archiver with data quality-period in 3600 seconds — create one at missing. :* ''OpenSCADA archiver for device's archive of days'' — set to the value archiver whole ID like to "FSArch.1d" for an archiver with data quality-period in 86400 seconds — create one at missing. :* ''OpenSCADA archiver for device's archive of months'' — set to the value archiver whole ID like to "FSArch.1m" for an archiver with data quality-period in 86400 seconds — create one at missing. :* ''OpenSCADA archiver for device's archive of Alarms'' — set to the message archiver whole ID like to "FSArch.alarms" for an archiver — create one at missing. :* ''Currents try period'' — to reading period of current values and last archive values. :* ''Time limit of processing of archiving'' — to time limit of execution the procedure during archives reading. :6. RESULT: The logical parameter object will perform interaction and placing of gathered data to the parameter attributes and archives. :7. In the process of the working, through the tab "Archiving" you have to select the archiving parameters in the used archivers to create the representative archives. :8. ... through the tab "Attributes" of operational data, in addition to obtaining the result, it is possible to perform operative setup and control on: :* ''Reset the archives reading and configuration'' — to reset positions of the archive reading. :* ''Set: ...'' — to set need device settings. |