From OpenSCADAWiki
Enter a message name below to show all available translations.
Found one translation.
Name | Current message text |
---|---|
h English (en) | {{CntHdr|Template IOs}} {| class="mw-collapsible mw-collapsed wikitable sortable" |+ style=white-space:nowrap | |- ! Identifier !! Parameter !! Type !! Mode !! Attribute !! Configuration !! Value |- | transport || Transport || String || Input || Not attribute || Constant || Serial.out_BK |- | addr || Device address [0...15] || Integer || Input || Not attribute || Constant || 1 |- | curRegul || Current values request in regular || Boolean || Input || Not attribute || Constant || 0 |- | arhH || OpenSCADA archiver for device's archive of hours || String || Input || Not attribute || Constant || |- | arhD || OpenSCADA archiver for device's archive of days || String || Input || Not attribute || Constant || |- | arhM || OpenSCADA archiver for device's archive of months || String || Input || Not attribute || Constant || |- | arhAlrm || OpenSCADA archiver for device's archive of Alarms || String || Input || Not attribute || Constant || |- | arhTryPer || Currents try period, seconds || Integer || Input || Not attribute || Constant || 3600 |- | arhTmLim || Time limit of processing of archiving, seconds || Integer || Input || Not attribute || Constant || 40 |- | reset || Reset the archives reading and configuration || Boolean || Input || Full access || Variable || |- | dtTm || Date and time || String || Output || Read only || Variable || |- | devSt || Device state || String || Output || Read only || Variable || |- | motoHours || Moto-hours || Integer || Input || Read only || Variable || |- | vWork || Volume: work || Real || Input || Read only || Variable || |- | vAccWork || Volume: accumulated work || Real || Input || Read only || Variable || |- | vResult || Volume: resume || Real || Input || Read only || Variable || |- | vAccResult || Volume: accumulated resume || Real || Input || Read only || Variable || |- | p || Pressure || Real || Input || Read only || Variable || |- | t || Temperature || Real || Input || Read only || Variable || |- | pFact || Pressing factor || Real || Input || Read only || Variable || |- | fWork || Flow: work || Real || Input || Read only || Variable || |- | fResult || Flow: resume || Real || Input || Read only || Variable || |- | stN2 || Set: Concentration N2 || Real || Output || Full access || Variable || |- | stCO2 || Set: Concentration CO2 || Real || Output || Full access || Variable || |- | stQ || Set: Gas density, kg/m3 || Real || Output || Full access || Variable || |- | stBP || Set: Barometric pressure, kgs/sm2 || Real || Output || Full access || Variable || |- | stSubPL || Set: Pressure substitution for lower border, kgs/sm2 || Real || Output || Full access || Variable || |- | stSubPH || Set: Pressure substitution for high border, kgs/sm3 || Real || Output || Full access || Variable || |- | stSubT || Set: Temperature substitution, °С || Real || Output || Full access || Variable || |- | stFH || Set: Flow maximum, m3/h || Real || Output || Full access || Variable || |- | stFL || Set: Flow minimum, m3/h || Real || Output || Full access || Variable || |- | stSubFL || Set: Flow substitution for lower border, m3/h || Real || Output || Full access || Variable || |- | stSubFH || Set: Flow substitution for high border, m3/h || Real || Output || Full access || Variable || |- | arhs || Archives object || Object || Output || Not attribute || Variable || |- | this || Object of the parameter || Object || Input || Not attribute || Variable || |- | f_stop || Function stop flag || Boolean || Input || Not attribute || Variable || 0 |- | f_start || Function start flag || Boolean || Input || Not attribute || Variable || 0 |- | f_err || Function error || String || Input || Not attribute || Variable || 0 |- | f_frq || Frequency of calculation of the function, Hz || Real || Input || Not attribute || Variable || 1000 |} |