Message definition (Sub-projects/Server )
'''Table 2:''' Hardware configuration of the OpenSCADA server. {| class="wikitable" |- ! Name !! Configuration !! Notes |- | CPU || AMD Phenom(tm) II X4 910e || AMD Phenom(tm) II energo-effective CPU * [2024-06] AMD Phenom(tm) II X4 910e purchased during performance improving with rising the power effectivity; * [2014-06] AMD Phenom(tm) II X4 900e purchased as used one instead of the original one Athlon 64 X2 (too weak) and the brand new one A8-6500, TDP 65W. |- | MB || GIGABYTE GA-M68MT-D3 AM3 DDR3 (NVIDIA® GeForce 7025/nForce 630a) | socket AM2/AM2+/AM3 main board * [2024-05] GA-M68MT-D3 purchased during performance improving with rising the power effectivity; * [2022-06] GA-M68M-S2P — replaces M2NPV-VM for reuse the actual configuration and CPU :* more reliable at using solid capacitors and big chipset radiator; :* lesser power consumption (CPU powering by 1V) — server common consumption at the low loading is 46W instead 56W. * [2014-06] M2NPV-VM — used but hard tested one and reliable one solution, instead purchased specially one of the brand new MB MSI A88X-G41 PC Mate. |- | Memory || 8GB (DDR3-1333) | DDR3,DDR2 memory * [2024-06] 2x4GB DDR3-1600 purchased during performance improving with rising the power effectivity; * [2022-06] brand new ones (4GB) after replacing MB where only two memory slots are; * [2014-06] mixed original ones for the Main Board (MB) and new ones (4GB). |- | HDD || 1TB, RAID1 (IRP-SSDPR-S25C-01T+KODAK-X120) | brand new ones, low power consumption ones, [[Special:MyLanguage/Sub-projects/Embedding_and_PLC#PerfStorages|heating about +8°C]] * [2024] SSD KODAK X120 PRO 1TB — replaces ST1000VM002 by weariness; * [2021] SSD IRP-SSDPR-S25C-01T — replaces broken WD10EZRX; * [2015] WD10EZRX+ST1000VM002 — replace previous ones due to 5400+5900 RPM; * [2014-06] 2 x DT01ACA050, 7200 RPM. |- | Power Supply || ATX Power Supply 350W FSP350-60EGN | Power Supply * [2024-08-14] used one FSP350-60EGN — replaces RS-400-PSAP-I3 by weariness; * [2014-06] brand new one RS-400-PSAP-I3. |- | Case || MidiTower, ATX || used one |- | UPS || Must EP21-0612PRO + LPM-MG12-65Ah + 3x12V16850BBlock || * '''''UPS-PowerInverter''''' :* [2025-07] Must EP21-0612PRO: ::* ''The output form'': [[:File:UPS_MustEP2100_OutCurve.png|a clean sine curve]] ::* ''Charging'': '''[5...20]A''' (configurable), up to '''[13.5...14.5]V''' (configurable) ::* ''Discharging down to'': '''[10...12]V''' (configurable) ::* ''Inverter effectivity'' [on 84W load]: 7.5A*12.2V = 92W = '''91%''' ::* ''Own consumption'': :::* from the battery: 0.7A * 12.5V = '''8.5W''' :::* from the powernet: '''7W''' (at BYPASS), '''7.8W''' (through the Inverter) :* [2016] PowerCom INF-800: ::* ''The output form'': [[:File:UPS_inf800.png|a clean sine curve]] ::* ''Charging'': '''~6A''', up to '''13.6V''' ::* ''Discharging down to'': '''~11.2V''' ::* ''Inverter effectivity'': '''~74%''', from 52Ah (at ~120W) / 70.5Ah (on self 25W) ::* ''Own consumption'': :::* from the battery, discharging on self (+23W): '''2.5(4.35)A'''*13.3(13.1)V = '''33(57)W''' :::* from the powernet (without the inverter): '''15(13)W''' :* ''The load measuring'': 100% = 480W * '''''12V Battery''''' — in summary '''144 Ah''' :* [2024-10] 12V16850BBlock3-29Ah assembled on 30 batteries INR18650 29E and the 3S 40A Balance board — replaces broken LPM-MG12-65Ah ::: [[file:at.png]] Outvalue on 1.7$ through Meest delivery to wrong address and followed local re-transmission by Oleksandr Prilepa (thanks for what) ::* ''2025-06-26'': Capacity = 12.7 Ah (11.3 V), '''26.9 Ah''' (10 V), 29.7 Ah ::* ''2024-10-18'': R = '''27 mOm''', Capacity = '''29.3 Ah''' :* [2024-02] 12V16850BBlock2-29Ah assembled on 30 batteries INR18650 29E and the 3S 40A Balance board — replaces broken LPM-MG12-65Ah ::* ''2025-06-15'': Capacity = 12.8 Ah (11.3 V), '''26.5 Ah''' (10 V), 29.3 Ah ::* ''2024-02-20'': R = '''27 mOm''', Capacity = '''30 Ah''' :* [2023-11] 12V16850BBlock1-29Ah assembled on 20 batteries INR18650 35E (degraded to 2.9Ah) + 10 INR18650 29E and the 3S 40A Balance board — replaces broken LPM-MG12-65Ah before the refurbishing ::* ''2025-07-11'' [Balance]: Capacity = 11.5 Ah (11.3 V), '''25 Ah''' (10 V), 26.6 Ah ::* ''2025-06-20'': Capacity = 10.4 Ah (11.3 V), '''23.5 Ah''' (10 V), 24.6 Ah ::* ''2024-07-21'': Capacity = >'''28.2 Ah''' ::* ''2024-02-28'': R = '''44 mOm''', Capacity = '''19.2 Ah''' ::* ''2023-11-01'': Capacity = '''19.5 Ah''' :* [2021-06] LPM-MG12-65Ah brand new one AGM MultiGel UPS buffer mode battery (2021-02) — replaces the previous broken — <span style="color:green">REFURBISHED</span> ::* ''2025-06-10'': Capacity = '''65 Ah''' ::* ''2024-10-19'': Capacity = '''4.0 Ah''' ::* ''2023-06-20'': Capacity = '''12.5 Ah''' (5 hours at 2.5A) ::* ''2022-06-29'': R = '''12 mOm''', Capacity = '''70.5 Ah''' (28.2 hours at 2.5A), Degradation = '''4.5 Ah/year''' ::* ''2021-06-18'': R = '''16 mOm''', Capacity = '''75 Ah''' (30 hours at 2.5A) :* [2019-06] LPM-MG12-65Ah brand new one AGM MultiGel UPS buffer mode battery (2018) — replaces the previous broken :* [2016-05] 6CT-60-A3 brand new one automobile starting battery |}
'''Table 2:''' Hardware configuration of the OpenSCADA server.
{| class="wikitable"
|-
! Name !! Configuration !! Notes
|-
| CPU || AMD Phenom(tm) II X4 910e || AMD Phenom(tm) II energo-effective CPU
* [2024-06] AMD Phenom(tm) II X4 910e purchased during performance improving with rising the power effectivity;
* [2014-06] AMD Phenom(tm) II X4 900e purchased as used one instead of the original one Athlon 64 X2 (too weak) and the brand new one A8-6500, TDP 65W.
|-
| MB || GIGABYTE GA-M68MT-D3 AM3 DDR3 (NVIDIA® GeForce 7025/nForce 630a)
| socket AM2/AM2+/AM3 main board
* [2024-05] GA-M68MT-D3 purchased during performance improving with rising the power effectivity;
* [2022-06] GA-M68M-S2P — replaces M2NPV-VM for reuse the actual configuration and CPU
:* more reliable at using solid capacitors and big chipset radiator;
:* lesser power consumption (CPU powering by 1V) — server common consumption at the low loading is 46W instead 56W.
* [2014-06] M2NPV-VM — used but hard tested one and reliable one solution, instead purchased specially one of the brand new MB MSI A88X-G41 PC Mate.
|-
| Memory || 8GB (DDR3-1333)
| DDR3,DDR2 memory
* [2024-06] 2x4GB DDR3-1600 purchased during performance improving with rising the power effectivity;
* [2022-06] brand new ones (4GB) after replacing MB where only two memory slots are;
* [2014-06] mixed original ones for the Main Board (MB) and new ones (4GB).
|-
| HDD || 1TB, RAID1 (IRP-SSDPR-S25C-01T+KODAK-X120)
| brand new ones, low power consumption ones, [[Special:MyLanguage/Sub-projects/Embedding_and_PLC#PerfStorages|heating about +8°C]]
* [2024] SSD KODAK X120 PRO 1TB — replaces ST1000VM002 by weariness;
* [2021] SSD IRP-SSDPR-S25C-01T — replaces broken WD10EZRX;
* [2015] WD10EZRX+ST1000VM002 — replace previous ones due to 5400+5900 RPM;
* [2014-06] 2 x DT01ACA050, 7200 RPM.
|-
| Power Supply || ATX Power Supply 350W FSP350-60EGN
| Power Supply
* [2024-08-14] used one FSP350-60EGN — replaces RS-400-PSAP-I3 by weariness;
* [2014-06] brand new one RS-400-PSAP-I3.
|-
| Case || MidiTower, ATX || used one
|-
| UPS || Must EP21-0612PRO + LPM-MG12-65Ah + 3x12V16850BBlock ||
* '''''UPS-PowerInverter'''''
:* [2025-07] Must EP21-0612PRO:
::* ''The output form'': [[:File:UPS_MustEP2100_OutCurve.png|a clean sine curve]]
::* ''Charging'': '''[5...20]A''' (configurable), up to '''[13.5...14.5]V''' (configurable)
::* ''Discharging down to'': '''[10...12]V''' (configurable)
::* ''Inverter effectivity'' [on 84W load]: 7.5A*12.2V = 92W = '''91%'''
::* ''Own consumption'':
:::* from the battery: 0.7A * 12.5V = '''8.5W'''
:::* from the powernet: '''7W''' (at BYPASS), '''7.8W''' (through the Inverter)
:* [2016] PowerCom INF-800:
::* ''The output form'': [[:File:UPS_inf800.png|a clean sine curve]]
::* ''Charging'': '''~6A''', up to '''13.6V'''
::* ''Discharging down to'': '''~11.2V'''
::* ''Inverter effectivity'': '''~74%''', from 52Ah (at ~120W) / 70.5Ah (on self 25W)
::* ''Own consumption'':
:::* from the battery, discharging on self (+23W): '''2.5(4.35)A'''*13.3(13.1)V = '''33(57)W'''
:::* from the powernet (without the inverter): '''15(13)W'''
:* ''The load measuring'': 100% = 480W
* '''''12V Battery''''' — in summary '''144 Ah'''
:* [2024-10] 12V16850BBlock3-29Ah assembled on 30 batteries INR18650 29E and the 3S 40A Balance board — replaces broken LPM-MG12-65Ah
::: [[file:at.png]] Outvalue on 1.7$ through Meest delivery to wrong address and followed local re-transmission by Oleksandr Prilepa (thanks for what)
::* ''2025-06-26'': Capacity = 12.7 Ah (11.3 V), '''26.9 Ah''' (10 V), 29.7 Ah
::* ''2024-10-18'': R = '''27 mOm''', Capacity = '''29.3 Ah'''
:* [2024-02] 12V16850BBlock2-29Ah assembled on 30 batteries INR18650 29E and the 3S 40A Balance board — replaces broken LPM-MG12-65Ah
::* ''2025-06-15'': Capacity = 12.8 Ah (11.3 V), '''26.5 Ah''' (10 V), 29.3 Ah
::* ''2024-02-20'': R = '''27 mOm''', Capacity = '''30 Ah'''
:* [2023-11] 12V16850BBlock1-29Ah assembled on 20 batteries INR18650 35E (degraded to 2.9Ah) + 10 INR18650 29E and the 3S 40A Balance board — replaces broken LPM-MG12-65Ah before the refurbishing
::* ''2025-07-11'' [Balance]: Capacity = 11.5 Ah (11.3 V), '''25 Ah''' (10 V), 26.6 Ah
::* ''2025-06-20'': Capacity = 10.4 Ah (11.3 V), '''23.5 Ah''' (10 V), 24.6 Ah
::* ''2024-07-21'': Capacity = >'''28.2 Ah'''
::* ''2024-02-28'': R = '''44 mOm''', Capacity = '''19.2 Ah'''
::* ''2023-11-01'': Capacity = '''19.5 Ah'''
:* [2021-06] LPM-MG12-65Ah brand new one AGM MultiGel UPS buffer mode battery (2021-02) — replaces the previous broken — <span style="color:green">REFURBISHED</span>
::* ''2025-06-10'': Capacity = '''65 Ah'''
::* ''2024-10-19'': Capacity = '''4.0 Ah'''
::* ''2023-06-20'': Capacity = '''12.5 Ah''' (5 hours at 2.5A)
::* ''2022-06-29'': R = '''12 mOm''', Capacity = '''70.5 Ah''' (28.2 hours at 2.5A), Degradation = '''4.5 Ah/year'''
::* ''2021-06-18'': R = '''16 mOm''', Capacity = '''75 Ah''' (30 hours at 2.5A)
:* [2019-06] LPM-MG12-65Ah brand new one AGM MultiGel UPS buffer mode battery (2018) — replaces the previous broken
:* [2016-05] 6CT-60-A3 brand new one automobile starting battery
|}